Goodrive35 inverters
Function
Name
code
QUICK/JOG
P07.02
function selection
Shifting sequence
P07.03
selection of
QUICK/JOG
Detailed instruction of parameters
2: Download the keypad function parameter to local
address (including the motor parameters)
3: Download the keypad function parameter to local
address (excluding the motor parameter of P02 and
P12 group)
4: Download the keypad function parameters to local
address (only for the motor parameter of P02 and
P12 group)
Note: After completing the 1 – 4 operations, the
parameter will come back to 0 automatically; the
function of upload and download excludes the factory
parameters of P29.
0: No function
1: Jogging. Press QUICK/JOG to begin the jogging
running.
2: Shift the display state by the shifting key. Press
QUICK/JOG to shift the displayed function code from
right to left.
3: Shift between forward rotations and reverse
rotations. Press QUICK/JOG to shift the direction of
the frequency commands. This function is only valid
in the keypad commands channels.
4: Clear UP/DOWN settings. Press QUICK/JOG to
clear the set value of UP/DOWN.
5: Coast to stop. Press QUICK/JOG to coast to stop.
6: Shift the given manner of running commands.
Press QUICK/JOG to shift the given manner of
running commands.
7: Quick commission mode (committee according to
the non-factory parameter)
Note: Press QUICK/JOG to shift between forward
rotation and reverse rotation, the inverter does not
remember the state after shifting during powering off.
The inverter will run in the running direction set
according to parameter P00.13 during next powering
on.
When P07.06=6, set the shifting sequence of running
command channels.
0: Keypad control→terminals control
80
Function parameters
Default
Mod
value
ify
◎
1
○
0
Need help?