3 Parameter Description
0-42 [Auto on] Key on LCP
Option:
[0]
Disabled
[1] *
Enabled
[2]
Password
3
0-43 [Reset] Key on LCP
Option:
[0]
Disabled
[1] *
Enabled
[2]
Password
3.2.7 0-5* Copy / Save
Copy parameter settings between set-ups and to/from the LCP.
0-50 LCP Copy
Option:
[0] *
No copy
[1]
All to LCP
[2]
All from LCP
[3]
Size indep. from LCP
This parameter cannot be adjusted while the motor is running.
0-51 Set-up Copy
Option:
[0] *
No copy
[1]
Copy to set-up 1
[2]
Copy to set-up 2
[3]
Copy to set-up 3
[4]
Copy to set-up 4
[9]
Copy to all
3.2.8 0-6* Password
Define password access to menus.
42
Function:
No function
[Auto on] Key is enabled
Avoid unauthorized start in Auto mode. If par.0-42
Personal Menu, then define the password in par.0-65
the password in par.0-60
Main Menu Password
Function:
No function
[Reset] Key is enabled
Avoid unauthorized resetting. If par.0-43
Menu
, then define the password in par.0-65
Main Menu Password
word in par.0-60
Function:
No function
Copies all parameters in all set-ups from the frequency converter memory to the LCP memory. For
service purposes it is recommended to copy all parameters to the LCP after commissioning.
Copies all parameters in all set-ups from the LCP memory to the frequency converter memory.
Copies only the parameters that are independent of the motor size. The latter selection can be used
to programme several frequency converters with the same function without disturbing motor data
which are already set.
Function:
No function
Copies all parameters in the present Programming Set-up (defined in par.0-11
up
) to Set-up 1.
Copies all parameters in the present Programming Set-up (defined in par.0-11
up
) to Set-up 2.
Copies all parameters in the present Programming Set-up (defined in par.0-11
up
) to Set-up 3.
Copies all parameters in the present Programming Set-up (defined in par.0-11
up
) to Set-up 4.
Copies the parameters in the present set-up over to each of the set-ups 1 to 4.
MG.11.N1.02 - VLT
®
is a registered Danfoss trademark
®
ADAP-KOOL
Drive Programming Guide
[Auto on] Key on LCP
Personal Menu Password
.
[Reset] Key on LCP
is included in the par. 0-25
Personal Menu Password
. Otherwise define the pass-
.
is included in the My
. Otherwise define
My Personal
Programming Set-
Programming Set-
Programming Set-
Programming Set-

Hide quick links: