3 Parameter Description
[39]
Display Text 3
[89]
Date and Time Readout
[1501]
Running Hours
[1502]
kWh Counter
[1600]
Control Word
3
[1601]
Reference [Unit]
[1602]
Reference [%]
[1603]
Status Word
[1605]
Main Actual Value [%]
[1609]
Custom Readout
[1610]
Power [kW]
[1611]
Power [hp]
[1612]
Motor Voltage
[1613]
Frequency
[1614]
Motor Current
[1615]
Frequency [%]
[1616]
Torque [Nm]
[1617]
Speed [RPM]
[1618]
Motor Thermal
[1622]
Torque [%]
[1630]
DC Link Voltage
[1632]
Brake Energy /s
[1633]
Brake Energy /2 min
[1634]
Heatsink Temp.
[1635]
Inverter Thermal
[1636]
Inv. Nom. Current
[1637]
Inv. Max. Current
[1638]
SL Controller State
[1639]
Control Card Temp.
[1650]
External Reference
[1652]
Feedback [Unit]
[1653]
Digi Pot Reference
[1654]
Feedback 1 [Unit]
[1655]
Feedback 2 [Unit]
36
Enables an individual text string to be written, for display in the LCP or to be read via serial com-
munication.
Displays the current date and time.
View the number of running hours of the motor.
View the mains power consumption in kWh.
View the Control Word sent from the frequency converter via the serial communication port in hex
code.
Total reference (sum of digital/analog/preset/bus/freeze ref./catch up and slow-down) in selected
unit.
Present status word
View the two-byte word sent with the Status word to the bus Master reporting the Main Actual Value.
View the user-defined readouts as defined in par.0-30
Readout Min Value
Custom Readout Max Value
and par.0-32
Actual power consumed by the motor in kW.
Actual power consumed by the motor in HP.
Voltage supplied to the motor.
Phase current of the motor measured as effective value.
Motor frequency, i.e. the output frequency from the frequency converter in percent.
Present motor load as a percentage of the rated motor torque.
Motor speed reference. Actual speed will depend on slip compensation being used (compensation
set in par.1-62
Slip Compensation
). If not used, actual speed will be the value read in the display
minus motor slip.
Thermal load on the motor, calculated by the ETR function. See also parameter group 1-9* Motor
Temperature.
Shows the actual torque produced, in percentage.
Intermediate circuit voltage in the frequency converter.
Present heat sink temperature of the frequency converter. The cut-out limit is 95 ± 5° C; cutting
back in occurs at 70 ± 5° C.
Nominal current of the frequency converter
Maximum current of the frequency converter
Temperature of the control card.
Sum of the external reference as a percentage, i.e. the sum of analog/pulse/bus.
Reference value from programmed digital input(s).
View the contribution of the digital potentiometer to the actual reference Feedback.
View the value of Feedback 1. See also par. 20-0*.
View the value of Feedback 2. See also par. 20-0*.
MG.11.N1.02 - VLT
®
is a registered Danfoss trademark
®
ADAP-KOOL
Drive Programming Guide
Custom Readout Unit
, par.0-31
.