Danfoss ADAP-KOOL Drive Programming Manual page 38

Hide thumbs Also See for ADAP-KOOL Drive:
Table of Contents

Advertisement

3 Parameter Description
[2117]
Ext. 1 Reference [Unit]
[2118]
Ext. 1 Feedback [Unit]
[2119]
Ext. 1 Output [%]
[2137]
Ext. 2 Reference [Unit]
[2138]
Ext. 2 Feedback [Unit]
3
[2139]
Ext. 2 Output [%]
[2157]
Ext. 3 Reference [Unit]
[2158]
Ext. 3 Feedback [Unit]
[2159]
Ext. 3 Output [%]
[2230]
No-Flow Power
[2580]
Pack Status
[2581]
Compressor Status
[2587]
Inverse Interlock
[2827]
Discharge Temperature
[3110]
Bypass Status Word
[3111]
Bypass Running Hours
[11675]
Wizard Init State
NB!
Please consult the
0-21 Display Line 1.2 Small
Option:
Application Dependent
0-22 Display Line 1.3 Small
Option:
Application Dependent
0-23 Display Line 2 Large
Option:
Application Dependent
0-24 Display Line 3 Large
Option:
Application Dependent
3.2.5 0-3*LCP Custom Readout
It is possible to customize the display elements for various purposes: *Custom Readout. Value proportional to speed (Linear, squared or cubed depending
on unit selected in par.0-30
Custom Readout
The calculated value to be displayed is based on settings in par.0-30
0-32
Custom Readout Max Value
38
The value of the reference for extended Closed Loop Controller 1
The value of the feedback signal for extended Closed Loop Controller 1
The value of the output from extended Closed Loop Controller 1
The value of the reference for extended Closed Loop Controller 2
The value of the feedback signal for extended Closed Loop Controller 2
The value of the output from extended Closed Loop Controller 2
The value of the reference for extended Closed Loop Controller 3
The value of the feedback signal for extended Closed Loop Controller 3
The value of the output from extended Closed Loop Controller 3
The calculated No Flow Power for the actual operating speed
ADAP-KOOL Drive AKD 102 Programming Guide, MG.11.CX.YY
Function:
Select a variable for display in line 1, middle position. The options are the same as listed for par.
0-20.
Function:
Select a variable for display in line 1, right position. The options are the same as listed for par. 0-20.
Function:
Select a variable for display in line 2. The options are the same as listed for par. 0-20.
Function:
Select a variable for display in line 3. The options are the same as listed for par. 0-20.
Custom Readout Unit
) *Display Text. Text string stored in a parameter.
, par.4-13
Motor Speed High Limit [RPM]
MG.11.N1.02 - VLT
ADAP-KOOL
for detailed information.
Custom Readout Unit
, par.0-31
Custom Readout Min Value
, par.4-14
Motor Speed High Limit [Hz]
®
is a registered Danfoss trademark
®
Drive Programming Guide
(linear only), par.
and actual speed.