ADAP-KOOL
AKD-LonWorks
1. Copyright
1. Copyright
1
1.1. Copyright
1.1.1. Copyright, Limitation of Liability and Revision Rights
This publication contains information proprietary to . By accepting and using this manual the user agrees that the information contained herein will be
used solely for operating equipment from or equipment from other vendors provided that such equipment is intended for communication with equipment
over a serial communication link. This publication is protected under the Copyright laws of Denmark and most other countries.
does not warrant that a software program produced according to the guidelines provided in this manual will function properly in every physical, hardware
or software environment.
Although has tested and reviewed the documentation within this manual, makes no warranty or representation, neither expressed nor implied, with
respect to this documentation, including its quality, performance, or fitness for a particular purpose.
I n no event shall be liable for direct, indirect, special, incidental, or consequential damages arising out of the use, or the inability to use information
contained in this manual, even if advised of the possibility of such damages. I n particular, is not responsible for any costs, including but not limited to
those incurred as a result of lost profits or revenue, loss or damage of equipment, loss of computer programs, loss of data, the costs to substitute these,
or any claims by third parties.
reserves the right to revise this publication at any time and to make changes to its contents without prior notice or any obligation to notify former or
present users of such revisions or changes.
1
MG.11.P1.02

Advertisement

Table of Contents
loading

Summary of Contents for Danfoss ADAP-KOOL

  • Page 1 ® ADAP-KOOL AKD-LonWorks 1. Copyright 1. Copyright 1.1. Copyright 1.1.1. Copyright, Limitation of Liability and Revision Rights This publication contains information proprietary to . By accepting and using this manual the user agrees that the information contained herein will be used solely for operating equipment from or equipment from other vendors provided that such equipment is intended for communication with equipment over a serial communication link.
  • Page 2 ® 2. Safety ADAP-KOOL AKD-LonWorks MG.11.P1.02...
  • Page 3: Safety Note

    I nstallation at High Altitudes By altitudes above 2 km, please contact Danfoss Drives regarding PELV. Warning against Unintended Start The motor can be brought to a stop by means of digital commands, bus commands, references or a local stop, while the frequency converter is connected to mains.
  • Page 4: Safety Regulations

    ® 2. Safety ADAP-KOOL AKD-LonWorks 2.1.2. Safety Regulations The frequency converter must be disconnected from mains if repair work is to be carried out. Check that the mains supply has been disconnected and that the necessary time has passed before removing motor and mains plugs.
  • Page 5 3.1.2. Assumptions These instructions assume, that the Danfoss AKD-LonWorks option is used in conjunction with a Danfoss AKD 102 frequency converter. I t is also assumed that the installed controller supports the interfaces described in this document and that all the requirements stipulated in the controller, as well as the frequency converter, are strictly observed along with all limitations therein.
  • Page 6 ® 3. I ntroduction ADAP-KOOL AKD-LonWorks 3.1.5. Abbreviations AC Knowledge Programmable Logic Controller Ampere Parameter Number BOOL Boolean Revolutions Per Minute Control Card Real Time Clock Seconds Control Word SCPT Standard Configuration Property Types Electromagnetic Compatibility SNVT Standard Network Variable Type...
  • Page 7: How To Install

    Status LED (green) The neuron I D is printed on the option in text and in barcode (code 39). 4.1.2. Cabling ® For information on cabling, please refer to data communication between ADAP-KOOL refrigeration controls RC8AC302. 4.1.3. Maximum Cable Lengths ®...
  • Page 8 AKD is the last controller on the LON cable. When the LON cable is connected to the gateway or System Manager, and the ADAP-KOOL address has been given in par. 11-90 (is only shown when the LON option is mounted in the frequency converter), press the Service Pin on the LON card. The address and Service Pin are also part of the Application Wizard.
  • Page 9 ® ADAP-KOOL AKD-LonWorks 4. How to I nstall MG.11.P1.02...
  • Page 10 ® 5. Connection to ADAP-KOOL System ADAP-KOOL AKD-LonWorks MG.11.P1.02...
  • Page 11 ® ADAP-KOOL AKD-LonWorks 5. Connection to ADAP-KOOL System 5. Connection to ADAP-KOOL System 5.1. Gatew ay After performing a Network Upload in AKM you should find the AKD. ⇒ Go to menu AKC Controllers in AKM to check and change settings.
  • Page 12: System Manager

    ® 5. Connection to ADAP-KOOL System ADAP-KOOL AKD-LonWorks 5.2. System Manager MG.11.P1.02...
  • Page 13 ® ADAP-KOOL AKD-LonWorks 5. Connection to ADAP-KOOL System MG.11.P1.02...
  • Page 14 6. How to I nstall Option in Frequency Con- ® verter ADAP-KOOL AKD-LonWorks MG.11.P1.02...
  • Page 15: How To I Nstall Option In Frequency Converter

    6. How to I nstall Option in Frequency Con- ® ADAP-KOOL AKD-LonWorks verter 6. How to I nstall Option in Frequency Converter 6.1.1. How to I nstall Option in Frequency Converter I tems required to install a fieldbus option in the frequency converter: The fieldbus option Fieldbus option adaptor frame for the AKD 102.
  • Page 16 6. How to I nstall Option in Frequency Con- ® verter ADAP-KOOL AKD-LonWorks I nstructions: Remove LCP panel from the AKD 102 Remove the frame located beneath and discard Push the option into place. Two positions are possible, with cable terminal facing either up or down...