Danfoss ADAP-KOOL Drive Programming Manual page 41

Hide thumbs Also See for ADAP-KOOL Drive:
Table of Contents

Advertisement

®
ADAP-KOOL
Drive Programming Guide
0-37 Display Text 1
Range:
0 N/A*
[0 - 0 N/A]
0-38 Display Text 2
Range:
0 N/A*
[0 - 0 N/A]
0-39 Display Text 3
Range:
0 N/A*
[0 - 0 N/A]
3.2.6 LCP Keypad, 0-4*
Enable, disable and password protect individual keys on the LCP.
0-40 [Hand on] Key on LCP
Option:
[0]
Disabled
[1] *
Enabled
[2]
Password
0-41 [Off] Key on LCP
Option:
[0]
Disabled
[1] *
Enabled
[2]
Password
Function:
In this parameter it is possible to write an individual text string for display in the LCP or to be read
via serial communication. If to be displayed permanently select Display Text 1 in par.0-20
Line 1.1 Small
Display Line 1.2 Small
, par. 0-21
Line 2 Large
Display Line 3 Large
or par. 0-24
character. Use the
and
buttons to move the cursor. When a character is highlighted by the
cursor, it can be changed. Use the
can be inserted by placing the cursor between two characters and pressing
Function:
In this parameter it is possible to write an individual text string for display in the LCP or to be read
via serial communication. If to be displayed permanently select Display Text 2 in par.0-20
Line 1.1 Small
, par. 0-21
Display Line 1.2 Small
Line 2 Large
Display Line 3 Large
or par. 0-24
character. Use the
and
buttons to move the cursor. When a character is highlighted by the
cursor, this character can be changed. A character can be inserted by placing the cursor between
two characters and pressing
or
Function:
In this parameter it is possible to write an individual text string for display in the LCP or to be read
via serial communication. If to be displayed permanently select Display Text 3 in par.0-20
Line 1.1 Small
,par. 0-21
Display Line 1.2 Small
Line 2 Large
Display Line 3 Large
or par. 0-24
character. Use the
and
buttons to move the cursor. When a character is highlighted by the
cursor, this character can be changed. A character can be inserted by placing the cursor between
two characters and pressing
or
Function:
No function
[Hand on] Key enabled
Avoid unauthorized start in Hand mode. If par.0-40
Personal Menu, then define the password in par.0-65
Main Menu Password
the password in par.0-60
Function:
No function
[Off] Key is enabled
Avoid unauthorized stop. If par.0-41
Personal Menu Password
define the password in par.0-65
Main Menu Password
0-60
.
MG.11.N1.02 - VLT
®
is a registered Danfoss trademark
3 Parameter Description
Display Line 1.3 Small
, par. 0-22
. Use the
or
buttons on the LCP to change a
or
buttons on the LCP to change a character. A character
, par. 0-22
Display Line 1.3 Small
. Use the
or
buttons on the LCP to change a
.
, par. 0-22
Display Line 1.3 Small
. Use the
or
buttons on the LCP to change a
.
[Hand on] Key on LCP
Personal Menu Password
.
[Off] Key on LCP
is included in the My Personal Menu, then
. Otherwise define the password in par.
Display
Display
, par. 0-23
3
or
.
Display
, par. 0-23
Display
Display
, par. 0-23
Display
is included in the My
. Otherwise define
41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents