Oil Cooler Inspection; Refitting The Oil Cooler - Ducati Monster 796 Workshop Manual

Hide thumbs Also See for Monster 796:
Table of Contents

Advertisement

Lubrication system: oil cooler
Note
The oil cooler can be removed complete with its hoses.

Oil cooler inspection

Visually inspect the oil cooler.
Renew the cooler at any sign of damage or leaks.

Refitting the oil cooler

Note
Lubricate the threads of the nipples (5) and (6) and union O-rings (E) with engine oil.
Fit the vibration damper mounts (2) in the holes of the oil cooler mounting brackets.
Insert spacer (3) fully home into the central vibration damper (2).
Fit the sealing washer (8) on the nipple (7).
Apply threadlocker to the thread of the nipple (7) that is screwed into the oil cooler.
Fit the nipple (7) with the gasket (8) in the supply port or in the return port and tighten it to a torque of 23 Nm ±10%
(Sect. 3 - 3,
Frame torque
Set the O-rings to nipples (7) and grease the O-rings with engine oil.
Attach the unions (A) to the nipples (7), finger-tightening the union nuts.
Tighten the unions (A) to a torque of 18 Nm ±5% (Sect.
settings) while restraining the hex nut of the radiator.
3 - 3,
Frame torque
settings).