Fitting A New Exhaust Valve Cable With Used Motor - Ducati Monster 796 Workshop Manual

Hide thumbs Also See for Monster 796:
Table of Contents

Advertisement

Maintenance operations
Disconnect the DDS.
Turn the key to on, let make one complete turn and make sure that the vertex of the hexagon (D) in-between the cable
mounting holes is secure/fixed next to the notch (B).
If the test result was positive in the previous step, proceed with the remaining operations. While if result was negative,
find failure cause before continuing.
Final checks
Make sure that, upon the following immediate "KEY ON" cycles, the exhaust valve stays in "fully open position", i.e. the
valve pulley rear tab must be resting against the stop plate welded to the exhaust pipe.

Fitting a new exhaust valve cable with used motor

Connect the DDS (Sect. 6 - 13,
Tester power
supply) and open the procedure "EXUP valve act.".
Press "F7" to open function "EXUP 50% test".