Maintenance operations
Brake fluid is corrosive and will damage paintwork. Avoid contact with eyes and skin. In the case of accidental contact,
wash the affected area thoroughly with plenty of running water.
Refill the tanks (2) and (7) with specified oil (Sect. 3 - 2,
Important
During the following operation, the fluid level must remain topped over the MIN mark all times. The end of the
transparent plastic pipe must remain immersed in the discharged fluid at all times.
Connect the bleed tool to bleed valve (5) or (8).
Operate the lever or the brake pedal and keep it actuated during the refilling.
Note
Follow the manufacturer's instructions when using a commercial brake bleeding tool.
Aspirate with bleeder and loosen the bleed valve (5) or (8) always checking that the level of the corresponding tank does
not fall below the MIN mark.
Continue this procedure until all the air is expelled from the system.
Tighten the bleed valve (5) to a torque of 4 Nm±10% and the valve (8) to a torque of 10 Nm±10% (Sect. 3 - 3,
torque
settings).
Fuel, lubricants and other