Upgrading A Tn2312Ap To A Tn2312Bp Ip Server Interface Circuit Pack; Setting Alarm Activation Level - Avaya S8700 Series Manual

Migrating
Hide thumbs Also See for S8700 Series:
Table of Contents

Advertisement

Upgrading a TN2312AP to a TN2312BP IP Server Interface
circuit pack
There may be an occasion when customers may want to upgrade their TN2312AP Internet
Protocol Server Interface (IPSI) circuit pack to a TN2312BP. For an S8700 or S8710 IP-Connect
configuration, the TN2312BP offers new functionality, including emergency transfer and CPE
alarming.
The TN2312BP also is required if the customer wants to move from duplex reliability to high
reliability in an IP Connect configuration. But this also requires that the customer use G650
Media Gateways.
You do not need to change any of the IPSI translations, assuming the functionality stays the
same. However, there is a new alarming feature that needs to be administered.
The TN2312BP Internet Protocol Server Interface (IPSI-2) circuit pack is a hot swappable item.
You do not need to power down the media gateway to replace it.

Setting alarm activation level

To set the alarm activation level:
1. Type change system-parameters maintenance and press Enter.
change system-parameters
maintenance
OPERATIONS SUPPORT PARAMETERS
CPE Alarm Activation Level: none
SCHEDULED MAINTENANCE
Update LSPs When Saving Translations: y
2. In the CPE Alarm Activation Level field, select none (default), warning, minor, or major,
depending on the level the customer wants.
194 Migrating to the Avaya S8700 Media Server
MAINTENANCE-RELATED SYSTEM PARAMETERS
Save Translation: daily
Command Time-out (hours): 2
Control Channel Interchange: no
System Clocks/IPSI Interchange: no
Start Time: 22 : 00
Stop Time: 06 : 00
Page 1 of 3

Advertisement

Table of Contents
loading

This manual is also suitable for:

S8700S8710

Table of Contents