Section 8
Measurement functions
8.1.6.2
8.1.6.3
8.1.6.4
Table 810:
IG Non group settings (Basic)
Parameter
Values (Range)
Operation
1=enable
5=disable
A Hi high limit res
0.00...40.00
A high limit res
0.00...40.00
A deadband res
100...100000
Table 811:
IG Non group settings (Advanced)
Parameter
Values (Range)
Measurement mode
1=RMS
2=DFT
914

Function block

A070778-ANSI V1 EN
Figure 471:
Function block
Signals
Table 808:
IG Input signals
Name
Type
IG
SIGNAL
BLOCK
BOOLEAN
Table 809:
IG Output signals
Name
Type
HIGH_ALARM
BOOLEAN
HIGH_WARN
BOOLEAN
Settings
Unit
Step
xIn
1
xIn
1
1
Unit
Step
Default
Description
0
Ground current
0=False
Block signal for all binary outputs
Description
High alarm
High warning
Default
Description
1=enable
Operation Disable / Enable
0.20
High alarm current limit
0.05
High warning current limit
2500
Deadband configuration value for integral
calculation. (percentage of difference between
min and max as 0,001 % s)
Default
Description
2=DFT
Selects used measurement mode