ABB Relion RED615 Manual
ABB Relion RED615 Manual

ABB Relion RED615 Manual

Line differential protection and control

Advertisement

Quick Links

®
Relion
615 series
Line Differential Protection and Control
RED615
DNP3 Point List Manual

Advertisement

Table of Contents
loading

Summary of Contents for ABB Relion RED615

  • Page 1 ® Relion 615 series Line Differential Protection and Control RED615 DNP3 Point List Manual...
  • Page 3 Document ID: 1MRS756879 Issued: 03.07.2009 Revision: A Product version: 2.0 © Copyright 2009 ABB. All rights reserved...
  • Page 4 Copyright This document and parts thereof must not be reproduced or copied without written permission from ABB, and the contents thereof must not be imparted to a third party, nor used for any unauthorized purpose. The software or hardware described in this document is furnished under a license and may be used, copied, or disclosed only in accordance with the terms of such license.
  • Page 5 In case any errors are detected, the reader is kindly requested to notify the manufacturer. Other than under explicit contractual commitments, in no event shall ABB be responsible or liable for any loss or damage resulting from the use of this manual or the application of the equipment.
  • Page 6 (EMC Directive 2004/108/EC) and concerning electrical equipment for use within specified voltage limits (Low-voltage directive 2006/95/EC). This conformity is the result of tests conducted by ABB in accordance with the product standards EN 50263 and EN 60255-26 for the EMC directive, and with the product standards EN 60255-6 and EN 60255-27 for the low voltage directive.
  • Page 7: Table Of Contents

    Table of contents Table of contents Section 1 Introduction...............3 This manual..................3 Intended audience................3 Product documentation...............4 Product documentation set............4 Document revision history.............5 Related documentation..............5 Document symbols and conventions..........6 Safety indication symbols..............6 Document conventions..............6 Functions, codes and symbols............7 Section 2 DNP3 data mappings............9 Overview.....................9 Point list for RED615 Ver.2.0 DE01-03..........10 Section 3 DNP3 protocol implementation........19...
  • Page 9: Section 1 Introduction

    Section 1 1MRS756879 A Introduction Section 1 Introduction This manual Point List Manual describes the outlook and properties of the data points specific to the IED. The manual should be used in conjunction with the corresponding Communication Protocol Manual. Intended audience This manual addresses the communication system engineer or system integrator responsible for pre-engineering and engineering for communication setup in a substation from an IED perspective.
  • Page 10: Product Documentation

    Section 1 1MRS756879 A Introduction Product documentation 1.3.1 Product documentation set Engineering manual Engineering manual Engineering manual Installation manual Installation manual Installation manual Commissioning manual Commissioning manual Commissioning manual Operation manual Operation manual Operation manual Service manual Service manual Service manual Application manual Application manual Application manual...
  • Page 11: Document Revision History

    Some of the manuals are not available yet. 1.3.2 Document revision history Document revision/date Product version History A/03.07.2009 First release Download the latest documents from the ABB web site http:// www.abb.com/substationautomation. 1.3.3 Related documentation Name of the document Document ID DNP3 Communication Protocol Manual...
  • Page 12: Document Symbols And Conventions

    Section 1 1MRS756879 A Introduction Document symbols and conventions 1.4.1 Safety indication symbols This publication includes icons that point out safety-related conditions or other important information. The caution icon indicates important information or warning related to the concept discussed in the text. It might indicate the presence of a hazard which could result in corruption of software or damage to equipment or property.
  • Page 13: Functions, Codes And Symbols

    Section 1 1MRS756879 A Introduction 1.4.3 Functions, codes and symbols Table 1: RED615 Functions, codes and symbols Functionality IEC 61850 IEC 60617 IEC-ANSI Protection Three-phase non-directional overcurrent PHLPTOC1 3I> (1) 51P-1 (1) protection, low stage, instance 1 Three-phase non-directional overcurrent PHHPTOC1 3I>>...
  • Page 14 Section 1 1MRS756879 A Introduction Functionality IEC 61850 IEC 60617 IEC-ANSI Master trip, instance 2 TRPPTRC2 Master Trip (2) 94/86 (2) Control Circuit-breaker control CBXCBR1 I ↔ O CB I ↔ O CB Disconnector position indication, DCSXSWI1 I ↔ O DC (1) I ↔...
  • Page 15: Section 2 Dnp3 Data Mappings

    Section 2 1MRS756879 A DNP3 data mappings Section 2 DNP3 data mappings Overview This document describes the DNP3 data points and structures available in RED615 Ver. 2.0. The data points are unmapped as a default.The point lists describe a superset of all data available through the standard configurations A, B and C including the optional functionalities.
  • Page 16: Point List For Red615 Ver.2.0 De01-03

    Section 2 1MRS756879 A DNP3 data mappings Point list for RED615 Ver.2.0 DE01-03 RED615 Point List Manual...
  • Page 17 Section 2 1MRS756879 A DNP3 data mappings RED615 Point List Manual...
  • Page 18 Section 2 1MRS756879 A DNP3 data mappings RED615 Point List Manual...
  • Page 19 Section 2 1MRS756879 A DNP3 data mappings RED615 Point List Manual...
  • Page 20 Section 2 1MRS756879 A DNP3 data mappings RED615 Point List Manual...
  • Page 21 Section 2 1MRS756879 A DNP3 data mappings RED615 Point List Manual...
  • Page 22 Section 2 1MRS756879 A DNP3 data mappings RED615 Point List Manual...
  • Page 23 Section 2 1MRS756879 A DNP3 data mappings RED615 Point List Manual...
  • Page 25: Section 3 Dnp3 Protocol Implementation

    Table 5: Device profile document DNP3 device profile document Vendor name: ABB Oy Device name: RED615 Highest DNP level supported: Device function: For requests: Level 2+ ○...
  • Page 26 Section 3 1MRS756879 A DNP3 protocol implementation DNP3 device profile document ○ Sometimes ● Configurable as: "Only when reporting event data", or "When reporting event data or multi-fragment messages" Timeouts while waiting for: Data link ○ None ○ Fixed at ____ ○...
  • Page 27: Dnp3 Implementation Table

    Section 3 1MRS756879 A DNP3 protocol implementation DNP3 device profile document ○ Configurable ○ When device restarts ○ Only certain objects ○ When status flags change ○ Sometimes (attach explanation) ○ ENABLE/DISABLE UNSOLICITED No other options are permitted. function codes supported Default counter object/variation: Counters roll over at: ●...
  • Page 28 Section 3 1MRS756879 A DNP3 protocol implementation Table 6: Implementation table OBJECT REQUEST (Library will parse) RESPONSE (Library will respond with) Object Variation Function codes Qualifier codes number number Description Function codes (dec) Qualifier codes (hex) (dec) (hex) Binary 1 (read) 00, 01 (start-stop) input –...
  • Page 29 Section 3 1MRS756879 A DNP3 protocol implementation OBJECT REQUEST (Library will parse) RESPONSE (Library will respond with) 16-bit 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop) 2 (default) analog 06 (no range, or all) 17, 28 (index) input 07, 08 (limited qty) 17, 28 (index) 32-bit...
  • Page 30 Section 3 1MRS756879 A DNP3 protocol implementation OBJECT REQUEST (Library will parse) RESPONSE (Library will respond with) Time delay 129 (response) 07 (limited qty) fine (qty = 1) Not defined Class 0 1 (read) 06 (no range, or all) data Class 1 1 (read) 06 (no range, or all)
  • Page 31: Section 4 Glossary

    Section 4 1MRS756879 A Glossary Section 4 Glossary Application function block library Autoreclosure Circuit breaker CROB Control output block Common time of occurrence. The time and date CTO object is an information object that represents the absolute time of day. Data attribute DNP3 A distributed network protocol originally developed by...
  • Page 36 Contact us ABB Oy Distribution Automation P.O. Box 699 FI-65101 VAASA, Finland Phone +358 10 22 11 +358 10 22 41094 www.abb.com/substationautomation...

This manual is also suitable for:

Relion 615 series