Output signals
Reaching of warning limits is reported via digital signals.
166 - Heat sink
temperature
8 -
warning
167 - Inside temperature
warning
9 -
170 -
Warning
overtemperature
12 -
1)
For linking to frequency inverter functions
2)
For output via a digital output.
14.3

Controller Status

The intervention of a controller can be indicated via the control unit or LED's. The selected control
methods and the matching monitoring functions prevent a switch-off of the frequency inverter. The
intervention of the function changes the operating behavior of the application and can be displayed
by the status messages with parameter
result in the intervention by the corresponding controller are described in the corresponding
chapters
The behavior during the intervention of a controller is configured with parameter
.
Controller-Status Message
Controller-Status
Message 409
0 - No message
1 – Warning Status
Warning status and
11 –
LED
Refer to Chapter 16.3.8 "16.3.8" and Chapter 16.3.8 "16.3.8" for a list of controllers and additional
controller status evaluation options.
14.4

IDC Compensation Limit

At the output of the frequency inverter a DC component can occur in the output current due to
unbalances. This DC voltage component can be compensated by the frequency inverter. The
maximum output voltage of the compensation is set with parameter
If a higher voltage than the set limit is needed for the compensation of a DC voltage component,
error "F1301 IDC COMPENSATION" is triggered.
If this fault occurs, it should be checked whether the load is defective. The voltage limit may have to
be increased.
If the parameter
IDC Compensation Limit
deactivated.
Parameter
No.
Description
415
IDC Compensation Limit
The factory setting of parameter
30 :
Configuration
1)
Configurations 1xx
12/16
1)
The value "80 °C minus
2)
Warning Limit Heat Sink Temp.
1)
The value "65 °C minus
2)
Warning Limit Inside Temp.
The value
1)
"80 °C minus
"65 °C minus
2)
was reached.
Controller Status
409.
The intervention of a controller is not reported.
The controllers influencing the operating behavior are displayed in the
Controller status 275 parameter.
The limitation by a controller is displayed as a warning by the control
unit.
The limitation by a controller is displayed as a warning by the control
unit and the LED's.
415 is reduced to zero, the DC compensation is
Min.
0.0 V
IDC Compensation Limit
2)
Configurations 2xx / 4xx / 5xx / 6xx
Operating Instructions ACU
407" was reached.
408" was reached.
Warning Limit Heat Sink Temp.
Warning Limit Inside Temp. Ti
275. The limit values and events which
Function
IDC Compensation Limit
Setting
Max.
1.5 V
415 depends on the setting of parameter
Tk 407" or
408"
415.
Factory setting
1)
1.5
2)
0.0
149