Via parameter
Technology Controller Release
current P and D portions are kept at the last value before shutdown. The output value and the I
portion will be deleted when
Note the default link of parameter
technology controller:
Start Clockwise
This link must not be changed. The technology controller becomes active with the
controller release at digital input S1IND/STOA.
Structural image: Inputs for reference percentage source
Repetition Frequency
Input
0
S2IND
S3IND
S6IND
Operation mode
Devider
Multifunctional Input
MFI1
Operation mode
The function selected via the parameter
technology controller.
Operation Mode 440
0 - off
1 - Standard
2 - Liquid Level 1
3 - Liquid Level 2
4 - Speed controller
Indirect
5 -
Volume Flow Control
12/16
58 , you can stop the technology controller. The
Technology Controller Release
68 = "13 – Technology Controller Start".
Technology Controller
Actual Percentage Source
F3
0
f
%
1
496
497
MFI1A
0
analog
1
digital
452
Operation Mode
The technology controller is switched off, the reference value
specification is done via the reference percentage channel.
For pressure and volume flow control with linear operating behavior
and actual value monitoring
Liquid Level control at defined motor speed with actual value missing
Liquid Level control at defined motor speed with actual value missing
or high control deviation
Speed control with analog feedback of the actual speed
Volume flow control with square rooted actual value.
Operating Instructions ACU
58 is turned off.
68 to the logic signal of the
Start Clockwise
478
Actual values
Istwerte:
+
Actual Percentage Value
440 defines the behavior of the
Function
230
213