BONFIGLIOLI ACTIVE CUBE 201 Operating Instructions Manual page 107

Frequency inverter 230 v/400 v, 0.25 kw...132 kw
Hide thumbs Also See for ACTIVE CUBE 201:
Table of Contents

Advertisement

SA031
Shorten Motor Line using Switchfrequ. 16 kHz.
SA032
Shorten Motor Line using Switchfrequ. 12 kHz and higher.
SA033
Shorten Motor Line using Switchfrequ. 8 kHz and higher.
SA041
The slip speed was not determined correctly. Check the values for parameters Rated Speed
372 and Rated Frequency 375 .
SA042
The slip speed was not determined correctly. Check the values for parameters Rated Speed
372 and Rated Frequency 375 .
SA051
The machine data for star connection were entered, the motor, however, is connected in
delta. For star operation, change the motor cable connection. For delta operation, check
the entered rated motor values.
Repeat the parameter identification
SA052
The machine data for delta connection were entered, the motor, however, is connected in
star. For delta operation, change the motor cable connection. For star operation, check the
entered rated motor values.
Repeat the parameter identification
SA053
A phase asymmetry was measured. Check the cables at the terminals of the motor and the
frequency inverter for proper connection and check the contacts for corrosion.
SA054
Resolver offset not adjusted.
12/16
Operating Instructions ACU