11.4

Speed Sensor 1

The frequency inverters are to be adapted to the application depending on the requirements. Some
of the available
Configurations
control functions and methods. The necessary connection of an incremental speed sensor is done on
the digital control terminals S5IND (track A) and S4IND (track B) of the frequency inverter.
With extension modules EM and sensor input modules, it is also possible to connect
and evaluate sensors as speed sensor 2. Please refer to the corresponding operating
instructions. Speed sensor 1 and speed sensor 2 are configured independently from
one another.
11.4.1

Operation Mode Speed Sensor 1

490 for speed sensor 1 can be selected according to the connected incremental
Operation Mode
speed sensor. A unipolar speed sensor is to be connected to the standard control terminals.
490
Operation Mode
0 - off
1 – Single Evaluation
Quadruple
4 –
Evaluation
Single
11 –
Evaluation 
 unsigned
Double Evaluation
12 –
unsigned
Single evaluation,
31 –
sense of rot. via
contact
Double Evaluation,
32 –
Dir. via contact
Single evaluation
101 –
inverted
Quadruple
104 –
evaluation
inverted
Single Evaluation
111 –
negative
Double Evaluation
112 –
negative
Single evaluation,
131 –
sense of rot. Cont.
inverted
Double Evaluation,
132 –
Dir. Cont. inverted
126
30 require continuous measurement of the actual speed for the
Speed measurement is not active; the digital inputs are available for
other functions.
Two-channel speed sensor with recognition of direction of rotation
via track signals A and B; one signal edge is evaluated per division
mark.
Two-channel speed sensor with recognition of direction of rotation
via track signals A and B; four signal edges are evaluated per division
mark.
One-channel speed sensor via track signal A; the actual speed value
is positive. One signal edge is evaluated per division mark. The digital
input S4IND is available for further functions.
One-channel speed sensor via track signal A; the actual speed value
is positive. Two signal edges are evaluated per division mark. The
digital input S4IND is available for further functions.
Single-channel speed sensor via track signal A. The actual speed
value is positive for signal "Low" and negative for signal "High" at
digital input S4IND. One signal edge is evaluated per division mark.
Single-channel speed sensor via track signal A. The actual speed
value is positive for signal "Low" and negative for signal "High" at
digital input S4IND. Two signal edges are evaluated per division
mark.
Like Operation Mode 1. The actual speed value is inverted.
(Alternative to exchanging the track signals)
Like Operation Mode 4. The actual speed value is inverted.
(Alternative to exchanging the track signals)
Like Operation Mode 11. Actual speed is negative.
Like Operation Mode 12. Actual speed is negative.
Single-channel speed sensor via track signal A. The actual speed
value is negative for signal "Low" and positive for signal "High" at
digital input S4IND. One signal edge is evaluated per division mark.
Single-channel speed sensor via track signal A. The actual speed
value is negative for signal "Low" and positive for signal "High" at
digital input S4IND. Two signal edges are evaluated per division
mark.
Operating Instructions ACU