BONFIGLIOLI ACTIVE CUBE 201 Operating Instructions Manual page 188

Frequency inverter 230 v/400 v, 0.25 kw...132 kw
Hide thumbs Also See for ACTIVE CUBE 201:
Table of Contents

Advertisement

Digital Inputs
74 -
S5IND
75 -
S6IND
76 -
MFI1D
157 - Warning mask
158 - Timer 1
159 - Timer 2
160 - Standby Message
161 - Run Signal
162 - Error Signal
Reference frequency
163 -
reached
164 - Setting Frequency
165 - Warning Ixt
Heat sink temperature
166 -
warning
Warning Inside
167 -
Temperature
Warning Motor
168 -
Temperature
169 - General Warning
170 - Warning overtemperature
171 - Output Comparator 1
Negated Output
172 -
Comparator 1
173 - Output Comparator 2
Negated Output
174 -
Comparator 2
175 - Digital Signal 1
176 - Digital Signal 2
177 - Digital Signal 3
Reference Percentage
178 -
reached
179 - Power Failure
188
Signal at digital input S5IND (X210A.7) or remote operation via
communication interface.
Signal at digital input S6IND (X210B.1) or remote operation via
communication interface.
Signal at multifunction input MFI1 (X210B.6) in
452 = "3 - Digital Input" or remove operation via
communication interface.
The defined warning mask of parameter
536 signals a critical operating point.
Output signal of the time function according to the input link
83.
Timer 1
Output signal of the time function according to the input link
84.
Timer 2
Frequency inverter is initialized and ready for operation.
Signal enable STO (S1IND/STOA and S7IND/STOB) and a start
command are present, output frequency available.
Monitoring function signals an operational fault.
Signal indicating when
reference frequency.
Signal indicating when the actual value
exceeds the value of
Setting Frequency
The monitoring functions report an overload of the frequency
inverter
Max. heat sink temperature T
Limit Heat Sink Temp.
Max. inside temperature T
408 reached.
Inside Temp.
Warning behavior according to parameterized
570 at max. motor temperature T
Operation Mode
Signal indicating that
Warnings
operating points.
The value
"80 °C minus
or
"65 °C minus
was reached.
The comparison according to the selected
540 is true.
Comparator 1
Operation mode 171 with inverted logic (LOW active)
The comparison according to the selected
543 is true.
Comparator 2
Operation mode 173 with inverted logic (LOW active)
Signal according to parameterized
530.
Signal according to parameterized
multifunction output MFO1.
Signal according to parameterized
532.
Signal indicating that
Actual Percentage Value
the Reference Percentage Value
Failure of mains voltage and mains support active according to
670 for the voltage controller.
Operation Mode
Operating Instructions ACU
Function
Create Warning Mask
241 has reached the
Actual Frequency
Stator Frequency
510.
of 80 °C minus the
K
Tk 407 reached.
of 65 °C minus the
i
269 are displayed at critical
Warning Limit Heat Sink Temp.
Warning Limit Inside Temp. Ti
Op. Mode
Op. Mode
Op. Mode Digital Output 1
Digital Operation
Op. Mode Digital Output 3
229 .
Operation Mode
210
Warning
Warning Limit
Motor Temp.
PTC.
Tk 407"
408"
554 at
230 has reached
12/16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Active cube 501Active cube 401Active cube 601

Table of Contents