BONFIGLIOLI ACTIVE CUBE 201 Operating Instructions Manual page 185

Frequency inverter 230 v/400 v, 0.25 kw...132 kw
Hide thumbs Also See for ACTIVE CUBE 201:
Table of Contents

Advertisement

Warning code
A
FFFF
FFFF
A
0000
FFFF
A
FFFF
0000
A
0000
0001
A
0000
0002
A
0000
0004
A
0000
0008
A
0000
0010
A
0000
0020
A
0000
0040
A
0000
0080
MTemp
A
0000
0100
Mains
A
0000
0200
A
0000
0400
A
0000
0800
A
0000
1000
A
0000
2000
Sysbus
A
0000
4000
A
0000
8000
WARN2
A
0001
0000
UDdyn
A
0002
0000
UDstop
A
0004
0000
UDctr
A
0008
0000
UDlim
A
0010
0000
A
0020
0000
A
0040
0000
A
0080
0000
A
0100
0000
A
0200
0000
IxtLtlim
A
0400
0000
IxtStlim
A
0800
0000
A
1000
0000
MtempLim
A
2000
0000
Output signals
The output of a warning is signaled.
1)
157 - Warning
2)
25 -
mask
1)
For linking to frequency inverter functions
2)
For output via a digital output.
Parameters
warnings independent of the created warning mask.
Parameters
display the controller status independent of the created warning mask.
12/16
-
1 - Activate everything
-
2 - Activate all warnings
-
3 - Activate all controller states
Ixt
10 - Warning Ixt
IxtSt
11 - Warning short-term Ixt
IxtLt
12 - Warning long-term Ixt
Tc
13 - Warning heat sink temperature
Ti
14 - Warning inside temperature
Lim
15 - Warning limit
INIT
16 - Warning Init
17 - Motor temperature warning
18 - Warning mains failure
PMS
19 - Warning motor circuit breaker
Flim
20 - Warning Fmax
A1
21 - Warning analog input MFI1A
A2
22 - Warning analog input MFI2A
23 - Warning system bus
UDC
24 - Warning Udc
25 - Warning, application
30 - Controller Udc dynamic operation
31 - Controller shutdown
32 - Controller mains failure
33 - Controller Udc limitation
Boost
34 - Controller voltage pre-control
Ilim
35 - Controller I abs
Tlim
36 - Controller torque limitation
Tctr
37 - Controller torque control
Rstp
38 - Ramp stop
39 - Contr. intel. curr. lim. LT-Ixt
40 - Contr. intel. curr. lim. ST-Ixt
Tclim
41 - Contr. intel. curr. lim. Tc
42 - Contr. intel. curr. lim. motor temp.
Flim
43 - Controller Freq. Limitation
Output of warning activated in
269 and
Warning
Controller Status
Operating Instructions ACU
Create Warning Mask 536
Create Warning Mask
356 (Error Environment ) display the
Warning
275 and
Controller Status
536.
355 (Error Environment )
185

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACTIVE CUBE 201 and is the answer not in the manual?

This manual is also suitable for:

Active cube 501Active cube 401Active cube 601

Table of Contents