low moment of inertia and/or a small load moment.
In operation modes 10 to 15, it cannot be ruled out that a wrong direction of rotation is determined
in quick synchronization. For example, a frequency not equal to zero may be determined although
the drive is at a standstill. If there is no overcurrent, the drive is accelerated accordingly. The
direction of rotation is defined in operation modes 11, 14 and 15.
The synchronization changes the parameterized starting behavior of the selected configuration. First,
the start command activates the search run in order to determine the rotary frequency of the drive.
In operation modes 1 to 5, the
percentage of
Rated Current
Parameter
No.
Description
647 Current / Rated Motor Current
The sensorless control is extended for the search run by a compensated proportional regulator,
which regulates the parameterized
integrating
part
648 and
Amplification
parameters to 0.
Parameter
No.
Description
648 Amplification
649 Integral Time
If the
Operation Mode Synchronisation
run), the search run is not started before the
If synchronization to the drive mechanism is not possible, the
into the motor in operation modes 1 to 5 for the duration of the
The impression of the direct current set in the parameters of the direct current brake leads to a
heating of the motor and should only be done for a short period in internally ventilated motors
Parameter
No.
Description
646 Brak. time after search run
NOTICE
The search run function is designed for operation with motors without brake. Brake
motors my not be operated perfectly with the search run function (depending on
parameterization and brake control.
12/16
Current / Rated Motor Current
371.
1.00 %
Current / Rated Motor Current
of
the
current
649. The control functions can be deactivated by setting the
Integral Time
645 parameter was set to operation mode 1 to 5 (search
Demagnetizing Time
Operating Instructions ACU
647 is used for synchronization as a
Setting
Min.
Max.
100.00 %
controller
can
be
Setting
Min.
Max.
0.00
10.00
0 ms
1000 ms
633 has elapsed.
Braking Current
Brak. Time after Search Run
Setting
Min.
Max.
0.0 s
200.0 s
Factory setting
70.00 %
647. The proportional and
set
via
parameters
Factory setting
1.00
20 ms
631 is impressed
Factory setting
10.0 s
646.