Technical data

Power
AC version
• 100-230 V AC ± 15%, 50 / 60 Hz, 36 VA (17W)
• Fuse: F3: 2 AG, Slow Blow, 0.375A, 250V
DC version
• 12-30 V DC, 20W
• Fuse: F3: 2 AG, Slow Blow, 2A, 250V
Mounting
Location
• Indoor / outdoor
Altitude
• 2000 m max.
Ambient temperature
• -20 to 50 °C (-5 to 122 °F)
Relative humidity
• Wall Mount: suitable for outdoors (Type 4X / NEMA 4X, IP65 Enclosure)
• Panel Mount: suitable for outdoors (Type 3 / NEMA 3, IP54 Enclosure)
Installation category
• II
Pollution degree
• 4
Range
• 0.3 m (1 ft) to 15 m (50 ft), dependent on transducer
1.
Power consumption is listed at maximum.