Technical data
12.1
Power
AC model
DC model
12.2
Performance
Range
Accuracy (measured under Reference Conditions similar to IEC 60770-1)
Resolution (measured under Reference Conditions similar to IEC 60770-1)
Temperature compensation
Source
Temperature error
Memory
288
•
100-230 V AC ±15%, 50 / 60 Hz, 36 VA (10W)
•
Fuse: 5 x 20 mm, Slow Blow, 0.25A, 250V
•
10-32 V DC, 10W (power consumption is listed at maximum)
•
Fuse: 5 x 20 mm, Slow Blow, 1.6A, 125V
•
0.3 to 60 m (1 to 196 ft), dependent on transducer
•
Standard operation: ±1 mm (0.04") plus 0.17 % of distance
•
±3 mm (0.12 inch) in combination with an XRS-5 transducer on 4 m (13 ft) range or less
•
High accuracy OCM
: ±1 mm (0.04"), within 3 m (9.84 ft) range
1)
•
Standard operation: 0.1 % of range or 2 mm (0.08"), whichever is greater
•
High accuracy OCM
: 1 mm (0.04")
1)
Reference operating conditions according to IEC 60770-1
•
ambient temperature +15 to +25 °C (+59 to +77 °F)
•
humidity 45% to 75% relative humidity
•
ambient pressure 860 to 1060 mbar g (86 000 to 106 000 N/m
Range: -40 to +150 °C (-40 to +300 °F)
•
Integral transducer sensor
•
TS-3 temperature sensor
•
Average (integral transducer and TS-3)
•
Programmable fixed temperature
Fixed
0.17 % per °C deviation from programmed value
•
512 kB flash EPROM
•
1.5 MB flash for data logging
1)
, within 3 m (9.84 ft) range
2)
Operating Instructions, 04/2021, A5E33329501-AG
12
g)
2
SITRANS LUT400