Technical Data - Siemens SIMOTION C 230-2 Operating Instructions Manual

Hide thumbs Also See for SIMOTION C 230-2:
Table of Contents

Advertisement

Technical data

11.1
Technical data
Memory for system data
Table 11-1
Data
Diagnostic buffer
RAM (Random Access Memory)
RAM disk (load memory)
Retentive memory
For information about user data, refer to chapter Properties of the user memory (Page 143).
Table 11-2
Data
Diagnostic buffer
RAM (Random Access Memory)
RAM disk (load memory)
Retentive memory
Note
If the C240/C240 PN is used as of software version V4.4 and as of a hardware version or FS "G",
you will have a RAM disk (load memory) of 29 MB and a RAM (Random Access Memory) of 67
MB.
If the C240/C240 PN as of a hardware version or FS "G" is operated as a spare part with older SW
versions, the previous values set for the corresponding SW version shall apply.
System clocks
Table 11-3
System clocks
Basic cycle clock (isochronous bus cycle not activated) 1.5 ms to 8 ms
DP cycle clock (isochronous bus cycle activated)
Position control cycle clock (servo cycle clock)
SIMOTION C
Operating Instructions, 11/2022, A5E33441428B
Memory for system data
Memory for system data (as of hardware version or FS "G")
System clocks
Memory size
C230-2
C240
200 messages
20 MB
23 MB
13 KB
Memory size
C240
C240 PN
200 messages
67 MB
29 MB
107 KB
C230-2
C240
1.5 ms to 8 ms
≥ 1.5 ms
11
C240 PN
40 MB
23 MB
107 KB
C240 PN
0.5 to 8 ms
1.0 to 8 ms
≥ 0.5 ms
163