HydroRanger 200 HMI – OPERATING INSTRUCTIONS
To reset the log after a short circuit on the transducer wiring, enter
the value -50.
Shows the lowest temperature encountered, as measured by theTS-3
Temperature Sensor (if applicable).
Global
Index
Range: - 50 to 150°C (Read only)
Values
Preset: 150°C
3.2.8.4. TS-3 Temperature Maximum
Related
To reset the log after an open circuit on the transducer wiring, enter
the value 150.
Sets the transducer index for all parameters applicable to this sub-
menu.
Displays the Long Echo Confidence of the measurement echo from
the last shot.
Transducer
Index
Range: 0 to 99
Values
2. 1 1.2.3. Long Echo Threshold
Related
2. 1 1.3.6. TVT Type
Use this feature to monitor the effect of transducer aiming, location,
and mechanical transducer/mounting isolation.
Displays the Short Echo Confidence of the measurement echo from
the last shot.
Transducer
Index
Range: 0 to 99
Values
2. 1 1.2.3. Long Echo Threshold
Related
2. 1 1.3.6. TVT Type
Use this feature to monitor the effect of transducer aiming, location,
and mechanical transducer/mounting isolation.
Displays the strength (in dB above 1 μV RMS) of the echo which was
selected as the measurement echo.
Transducer
Index
Range: 0 to 99 (Read only)
Values
Displays the average ambient noise (in dB above 1 μV RMS) of a noise
profile after each measurement.
A5E36281317