Auxiliary Reading - Siemens HydroRanger 200 HMI Operating Instructions Manual

Ultrasonic controllers
Hide thumbs Also See for HydroRanger 200 HMI:
Table of Contents

Advertisement

Display field descriptions
Display field
Tag
Primary Reading
type
Primary Reading
Point Identifier
Current View Num-
ber
Primary Reading
Units
Level Alarm Status
(high/low)
Level Bar Graph
Filling/Emptying
Discrete Inputs
(active/inactive)
Relays
Fault Text
Fault Number
Device Status Indi-
cator
Fault Point

Auxiliary Reading

Units
Auxiliary Reading
Auxiliary Reading
Name
Auxiliary Reading
Measurement View 2 displays an Auxiliary Reading area in addition to the Primary
Reading. The Auxiliary Reading can display additional information that you choose.
Setting a specific Auxiliary Reading
To set the value initially displayed in the Auxiliary Reading, use parameter
Auxiliary Reading
The Auxiliary Reading value that you choose is automatically synchronized with the
Primary Reading value as the display scrolls through the Level Points. For example, if the
A5E36281317
HydroRanger 200 HMI – OPERATING INSTRUCTIONS
Description
A short description that can be set using parameter
Identifies the type of measurement shown in the Primary Reading field.
Displays the value of the Primary Reading. This value is selected by using a
Quick Start Wizard or parameter
more information on how to select a value.
Level Point number for data currently displayed. See Measurement View
scrolling for more information.
Displays the number of the Measurement View (1 or 2).
The measurement of units corresponding to the Primary Reading. The field
will be blank if the Primary Reading has no units.
Show the Hi/Hi-Hi and Lo/Lo-Lo level alarm statuses. Will display if one or
more relays have been programmed for level alarms. See parameter
Relay Function
for information about programming level alarms.
Bar graph indicator that visually represents the level of the Point being dis-
played
Indicates if the level is rising or falling. See parameters
tor
2.3. 1 0. Emptying Indicator
and
Displays information about which discrete inputs are programmed and the
current state of each input. Discrete inputs are used to trigger or alter the
way the HydroRanger 200 HMI controls devices such as pumps and
alarms.
Information about which relays are programmed and what the current
states of each relay are.
If there is a fault, this displays the description of the active fault. If there is
no fault, the field will appear blank.
If there is an active fault, this field displays the number of the fault. See
General fault codes
on page 213 for descriptions of possible faults.
If two faults are present at the same time, the device status indicator and
text for the highest priority will display.
The point number (1 or 2) of the fault.
The measurement units corresponding to the Auxiliary Reading. The field
will appear blank if the Auxiliary Reading has no units.
Displays the value of the Auxiliary Reading. The value shown here is
selected using parameter
Reading below for more information on how to select the value display.
Identifies the value shown in the Auxiliary Reading field.
.
2. 1 .3. Sensor Mode
for information about programming.
2. 1 2.7. Default Auxiliary Reading
3. 1 . 1 . Tag
. See Operation for
2.8. 1 .4.
2.3.9. Filling Indica-
. See Auxiliary
2.12.7. Default