4 Repair
4.7.3 Replacement of motor and timing belt, axis 3
Continued
4
5
Continues on next page
168
Action
Cut the cable ties to simplify accessing
the motor.
Disconnect motor connectors.
© Copyright 2004-2013 ABB. All rights reserved.
Note
xx0200000449
A: Cable ties
B: Pressurized air hose
C: Power cables, axes 4, 5 and 6
D: Customer cables, signal
E: Signal cables, axes 4, 5 and 6
F: Signal cable, axis 3
G: Connectors R3.MP3 and R3.FB3
Connectors:
R3.MP3
R3.FB3
R3.H1 (if Safety lamp is fitted)
R3.H2 (if Safety lamp is fitted)
3HAC027400-001 Revision: K