HP MC68360 User Manual page 459

Emulator / analyzer graphical user interface
Table of Contents

Advertisement

Chapter 12: Emulator Error Messages
Unmatched quote encountered (Error 820)
Unmatched quote encountered (Error 820)
Cause: In entering a string, such as with the echo command, you didn't properly
match the string delimiters (either '' or ""). For example, you might have entered
echo "set S1 to off
Action: Reenter the command and string, making sure to properly match opening
and closing delimiters. Note that both delimiters must be the same character. For
example: echo "set S1 to off".
Update HP64740 firmware to version A.02.02 or newer (Error 163)
Cause: This error occurred when you attempted to disassemble a trace and the
analyzer firmware was found to be out of date.
Action: Refer to Chapter 15, "Installing/Updating Emulator Firmware". You must
update the firmware to the version number specified in the message, or newer
firmware version number. Your system is not usable with its present firmware.
Write to ROM break:<ROM address> (Async_Stat 628)
Cause: This status message indicates the target program accessed memory mapped
as either emulation ROM or target ROM; the emulator interrupted target execution
and began running in the monitor. This only occurs if you enabled breaks on writes
to ROM.