HP MC68360 User Manual page 448

Emulator / analyzer graphical user interface
Table of Contents

Advertisement

Chapter 12: Emulator Error Messages
Range resource in use (Error 1221)
Range resource in use (Error 1221)
Cause: This error occurs when you attempt to redefine the "complex" configuration
range resource while it is currently being used as a qualifier in the trace
specification.
Action: In the "complex" configuration, display the sequencer specification to see
where the range resource is being used and remove it; then, you can redefine the
range resource.
Range term used more than once (Error 1248)
Cause: This error occurs when you attempt to use the range resource more than
once in a sequencer branch expression.
Action: Do not try to use the range resource more than once in a sequencer branch
expression.
Read PC failed during break (Error 603)
Cause: The monitor is not responding.
Action: Check your target system configuration, the emulator configuration and
memory map, or reinitialize the emulator. Then try the command sequence again.
Record checksum failure (Error 400)
Cause: During a transfer operation, the checksum specified in a file did not agree
with that calculated by the HP 64700.
Action: Retry the transfer operation. If the failure is repeated, make sure that both
your host and the HP 64700 data communications parameters are configured
correctly.
Records expected: <number>; records received: <number> (Error 401)
Cause: The HP 64700 received a different number of records than it expected to
receive during a transfer operation.
Action: Retry the transfer. If the failure is repeated, make sure the data
communications parameters are set correctly on the host and on the HP 64700. See
the HP 64700-Series Card Cage Installation/Service Guide for details.