Chapter 12: Emulator Error Messages
Count qualifier not available with current clock speed (Error 1240)
Count qualifier not available with current clock speed (Error 1240)
Cause: This error occurs when you attempt to specify the "time" count qualifier
when the current maximum qualified clock speed is fast (F) or very fast (VF). This
error also occurs when you attempt to specify a "state" count qualifier when the
maximum qualified clock speed is fast (F).
Action: Change the clock speed; then change the count qualifier. See Chapter 7,
"Using the Emulation-Bus Analyzer", for more information.
Coverage not supported (Error 160)
Cause: The memory coverage command cannot be used in this emulator because
there is no supporting hardware.
Disable breakpoint failed: <address> (Error 604)
Cause: System failure or target condition.
Action: Emulator was unable to write previously saved opcode to target memory.
Check target memory system.
Disable breakpoint failed: <address> (Error 666)
Cause: System failure or target condition.
Action: Check memory mapping and configuration questions. This message is
usually accompanied by other messages. Look at those messages to better
understand the error and know which actions to take.
Display register failed: <register> (Error 634)
Cause: The emulator was unable to display the register you requested.
Action: To resolve this, you must look at the other status messages displayed. It is
likely that the emulator was unable to break to the monitor to perform the register