Chapter 12: Emulator Error Messages
Clock speed not available with current count qualifier (Error 1239)
Clock speed not available with current count qualifier (Error 1239)
Cause: This error occurs when you attempt to specify a fast (F) or very fast (VF)
maximum qualified clock speed when the analyzer is counting time. This error also
occurs when you attempt to specify a very fast (VF) maximum qualified clock
speed when the analyzer is counting states.
Action: Change the count qualifier; then reenter the command. See Chapter 7,
"Using the Emulation-Bus Analyzer", for more information.
CMB execute break (Error 623)
Cause: This message occurs when coordinated measurements are enabled and an
EXECUTE pulse causes the emulator to run. The emulator must break before
running. This is a status message; no action is required.
CMB execute; emulation trace started (Error 1305)
Cause: This status message informs you that an emulation trace measurement has
started as a result of a CMB execute signal (as specified by the "specify trace"
command).
CMB execute; run started (Async_Stat 693)
Cause: This status message is displayed when you are making coordinated
measurements. The CMB/EXECUTE pulse has been received; the emulation
processor started running at the address specified by the "specify run" command.
CMB trigger break (Async_Stat 617)
Cause: This status message will be displayed if you have configured the emulator
to break on a CMB trigger and the CMB trigger line is activated during a program
run. The emulator is broken to the monitor.
Command line too complex (Error 814)
Cause: There was not enough memory for the expressions in the command line.
Action: Split up the command line, or use fewer expressions.