Changing the Interface Settings

This section shows you how to:
Set the source/symbol modes.
Set the display modes.

To set the source/symbol modes

• To display assembly language mnemonics with absolute addresses, choose
Settings→Source/Symbol Modes→Absolute, or, using the command line, enter
the set source off symbols off command.
• To display assembly language mnemonics with absolute addresses replaced by
global and local symbols where possible, choose Settings→Source/Symbol
Modes→Symbols, or, using the command line, enter the set source off symbols
on command.
• To display assembly language mnemonics intermixed with high-level source lines,
choose Settings→Source/Symbol Modes→Source Mixed, or, using the command
line, enter the set source on symbols on command.
• To display only high-level source lines, choose Settings→Source/Symbol
Modes→Source Only, or, using the command line, enter the set source only
symbols on command.
The source/symbol modes affect mnemonic memory displays and trace displays.
Each display mode cascade menu choice is a toggle. Choosing one of these items
causes it to be the only one active and toggles all others off. Provided that symbols
were loaded, the interface defaults to:
Source only for mnemonic memory displays.
Source mixed for trace listing displays.