HP MC68360 User Manual page 442

Emulator / analyzer graphical user interface
Table of Contents

Advertisement

Chapter 12: Emulator Error Messages
Invalid number of arguments (Error 308)
Invalid number of arguments (Error 308)
Cause: You either entered too many options to a command or an insufficient
number of options.
Action: Reenter the command with correct syntax. Use online help by typing help
<command>. Refer to Chapter 11, "Emulator/Analyzer Interface Commands", in
this manual for more information.
Invalid occurrence count: <number> (Error 1234)
Cause: Occurrence counts may be from 1 to 65535.
Action: Reenter the command with a valid occurrence count.
Invalid option or operand (Error 300)
Invalid option or operand: <option> (Error 305)
Cause: You have specified an incorrect option to a command. <option>, if printed,
indicates the incorrect option.
Action: Use online help by typing help <command> or ? <command>. Reenter
the command with the correct syntax. Refer to Chapter 11, "Emulator/Analyzer
Interface Commands", for more information.
Invalid pod number: <pod#> (Error 1253)
Cause: This error message occurs when you attempt to specify a slave clock for a
non-existent analyzer pod.
Action: Use the trace activity command to display the valid pod numbers, and use
only these numbers when entering commands.
Invalid qualifier resource or operator: <expression> (Error 1241)
Cause: When specifying complex expressions, you have either specified an illegal
pattern or used an illegal operator.
Action: See Chapter 7, "Using the Emulation-Bus Analyzer", for more information.
422