Chapter 12: Emulator Error Messages
Number must be a multiple of 1000H
Number must be a multiple of 1000H
Cause: A number other than a multiple of 1000H was entered for the base address
of the foreground monitor during configuration.
Action: Use a number that is a multiple of 1000H for the base address of the
foreground monitor.
One sequence term required (Error 1228)
Cause: This error occurs when you attempt to delete terms from the sequencer
when only one term exists.
Action: At least one term must exist in the sequencer. Do not attempt to delete
sequence terms when only one exists.
Out of system memory (Error 201)
Cause: Macros and equates that you have defined have used all of the available
system memory.
Action: Delete some of the existing macros and equates. This will free additional
memory.
Program counter is located in guarded memory (Error 150)
Cause: The address contained in the program counter is an address in guarded
memory.
Action: Write a valid address into the program counter.
Program counter is odd (Error 84)
Cause: You attempted to modify the program counter to an odd value using the
modify registers command on a processor that expects even alignment of opcodes.
Action: Modify the program counter only to even numbered values.