HP MC68360 User Manual page 451

Emulator / analyzer graphical user interface
Table of Contents

Advertisement

Chapter 12: Emulator Error Messages
Sequence term number out of range: <term> (Error 1224)
Sequence term number out of range: <term> (Error 1224)
Cause: This error occurs when a sequencer qualification command specifies a
non-existent sequence term. The easy configuration sequencer may have a
maximum of four sequence terms. Eight sequence terms exist in the complex
configuration sequencer.
Action: Reenter the command using an existing sequence term.
Severe error detected, file transfer failed (Error 411)
Cause: An unrecoverable error occurred during a transfer operation.
Action: Retry the transfer. If it fails again, make sure the data communications
parameters are set correctly on the host and on the HP 64700. Also make sure you
are using the correct command options, both on the HP 64700 and on the host.
Software breakpoint: <breakpoint address> (Async_Stat 615)
Cause: This status message indicates that the target program executed a software
breakpoint instruction (an execution breakpoint, either in software or provided by
one of the eight hardware breakpoint resources). The emulator stopped the target
program and began running in the monitor.
Software breakpoint break condition is disabled (Error 661)
Cause: You disabled the software breakpoint feature. Breakpoints are enabled by
default. Then you attempted to set a breakpoint, or you attempted to single step
with the foreground monitor (either the built-in or custom foreground monitor).
Action: Re-enable the software breakpoint feature and try again.
Specified breakpoint not in list: <address> (Error 663)
You tried to enable a software breakpoint that was not previously defined.
<address> prints the address of the breakpoint you attempted to enable. Insert the
breakpoint into the table and memory.