HP MC68360 User Manual page 414

Emulator / analyzer graphical user interface
Table of Contents

Advertisement

Chapter 11: Emulator/Analyzer Interface Commands
trace
screen, the current trace automatically updates the display. If the trace memory
contents exceed the page size of the display, the <NEXT>, <PREV>, <Up arrow>,
or <Down arrow> keys may be used to display all the trace memory contents. You
also can press <CTRL>f and <CTRL>g to move the display left and right.
You can set up trigger and storage qualifications using the specify trace command.
The analyzers will begin tracing when a cmb_execute command executes, which
causes an EXECUTE signal on the Coordinated Measurement Bus.
The analyzer will trace any state by default.
The parameters are as follows:
again
This option repeats the previous trace measurement. It also begins a trace
measurement with a newly loaded trace specification. (Using trace without the
again parameter will start a trace with the default specification rather than the
loaded specification.)
anything
This causes the analyzer to capture any type of information.
arm_trig2
This option allows you to specify the external trigger as a trace qualifier, for
coordinating measurements between multiple HP 64700s, or an HP 64700 and
another instrument.
Before arm_trig2 can appear as an option, you must modify the emulation
configuration interactive measurement specification. When doing this, you must
specify that either BNC or CMBT drive trig2, and that the analyzer receive trig2.
See Chapter 9, "Making Coordinated Measurements", for more information.
break_on_trigger
This stops target system program execution when the trigger is found. The
emulator begins execution in the emulation monitor. When using this option, the
on_halt option cannot be included in the command.
modify_command
This recalls the last trace command that was executed.
on_halt
When using this option, the analyzer will continue to capture states until the
emulation processor halts or until a stop_trace command is executed. When this
option is used, the break_on_trigger, repetitively, and TRIGGER options cannot
be included in the command.
only
This option allows you to qualify the states that are stored, as defined by
QUALIFIER.
prestore
This option instructs the analyzer to save specific states that occur prior to states
that are stored (as specified with the "only" option).
394