display trace
The offset_by option subtracts the specified offset from the addresses of the
executed instructions before listing the trace. With an appropriate entry for offset,
each instruction in the listed trace will appear as it does in the assembled or
compiled program listing.
The count parameter lists the time associated with a trace event either relative to
the previous event in the trace list or as an absolute count measured from the
trigger event.
The source parameter allows display of source program lines in the trace listing,
enabling you to quickly correlate the trace list with your source program.
Initial values are the same as specified by the command:
display trace mnemonic count relative offset_by 0
<RETURN>
The parameters are as follows:
absolute
Lists trace information in hexadecimal format, rather than mnemonic opcodes.
count
absolute
This lists the time count for each event of the trace as the total time measured from
the trigger event.
relative
This lists the time count for each event of the trace as the time measured relative to
the previous event.
depth
<DEPTH#>
This defines the number of states to be uploaded by the interface.
Note that after you have changed the trace depth, execute the command wait
measurement_complete before displaying the trace. Otherwise the new trace
states will not be available.
disassemble
Displays the trace at a certain line number and disassembles instruction opcodes.
_from_line
_number
--EXPR--
An expression is a combination of numeric values, symbols, operators, and
parentheses, specifying an offset value to be subtracted from the addresses traced
by the emulation analyzer. See the EXPR syntax diagram.