Chapter 9: Making Coordinated Measurements
Using Trigger Signals
To arm the emulation analyzer on signal from
CMB
1 Choose "drive" for the "Should CMBT drive or receive Trig2" configuration option.
2 Choose "receive" for the "Should Analyzer drive or receive Trig2" configuration
option.
3 Use the arm_trig2 option to the trace command.
To arm the emulation analyzer on signal from
BNC
1 Choose "drive" for the "Should BNC drive or receive Trig2" configuration option.
2 Choose "receive" for the "Should Analyzer drive or receive Trig2" configuration
option.
3 Use the arm_trig2 option to the trace command.