Chapter 12: Emulator Error Messages
Trigger position out of bounds: <bounds> (Error 1202)
Trigger position out of bounds: <bounds> (Error 1202)
Cause: This error occurs when you attempt to specify a number of lines to appear
either before or after the trigger which is greater than the number of lines allowed.
The <bounds> string indicates the incorrect range you typed (not the correct limits
on the range).
Action: Be sure that the trigger position specified is within the range -1024 to 1023
(or -512 to 511 if counting is enabled).
trig1 break (Async_Stat 618)
Cause: This status message will be displayed if you used the break_on_trigger
syntax of the trace command and the analyzer has found the trigger condition
while tracing a program run. The emulator is broken to the monitor.
Trig1 signal cannot be driven and received (Error 1302)
Cause: This error occurs when you attempt to specify the internal trig1 signal as the
trace arm condition while the same analyzer's trigger output is currently driving the
trig1 signal. This error also occurs if you attempt to specify that the trigger output
drive the internal trig1 signal while that signal is currently specified as the arm
condition for the same analyzer.
Action: You can either change the arm or the trigger output specification; in either
case, make sure they do not use the same internal signal.
trig2 break (Async_Stat 619)
This status message will be displayed if you have used the internal trig2 line to
connect the analyzer trigger output to the emulator break input and the analyzer has
found the trigger condition. The emulator is broken to the monitor.
Trig2 signal cannot be driven and received (Error 1303)
Cause: This error occurs when you attempt to specify the internal trig2 signal as the
trace arm condition while the same analyzer's trigger output is currently driving the
trig2 signal. This error also occurs if you attempt to specify that the trigger output
drive the internal trig2 signal while that signal is currently specified as the arm
condition for the same analyzer.
Action: You can either change the arm or the trigger output specification; in either
case, make sure they do not use the same internal signal.