4. When exit time has expired, the keypad will display
the Part On icon.
5. To turn the system off, enter your PIN, then press
[OFF].
Turning The System Off
When the system is on, you must enter through a designated
entry door to prevent an alarm. Opening a designated
door (e.g. front door) will start the entry timer. During entry
time, the keypad will emit a pulsing tone "beep" to remind
you to turn the system off. To turn the area off, enter your
PIN followed by the [OFF] key before the entry delay time
expires.
If you enter through the wrong door or fail to turn the
system off before the entry delay time expires, you may
sound an alarm. If an alarm occurs, silence the alarm
(by entering your PIN followed by the [OFF] key) and call
your security company to let them know that it is not an
emergency situation.
1. Enter your PIN + [OFF] to turn the system (or area)
off. The keypad will display the 'Off' icon.

Silencing Alarms

When the system has registered an alarm, the keypad
(s) and sirens will sound to alert personnel that an alarm
occurred. The zone or zones which triggered the alarm will
be flashing on the keypad display for visual feedback. If
you enter your PIN before the system dials your security
company, the alarm report is cancelled (if programmed).
1. Enter your PIN + [OFF] to silence any alarm and turn
the system off. The keypad will continue to flash the
zone indicator of the zone which caused the alarm.
This is called alarm memory.
2. To clear alarm memory, turn the area on and off
again (eg. PIN + [ON] + PIN + [OFF].

Automatic Arming

Your system may have been programmed to automatically
arm itself at a certain time of the day.
If for some reason you are still in the building when the
auto arming is taking place then it is possible to extend
or delay the auto-on time (automatic arming time) by one
hour if required. The auto-on pre-alert time sounds the
keypad buzzer and displays the word AUTO on the display
to warn you.
To delay, enter your PIN + [OFF] key. The system will prompt
with the word Delay? Press [OK] to confirm that you want
to delay the arming sequence.
Bosch Security Systems 10/07 BLCC500U FTR1.01
Example:
If the control panel is programmed by your installer to
automatically turn All On at 6:00pm and the auto-on pre-
alert time starts beeping the keypad at 5:55pm, enter your
PIN+[OK] and then when prompted press [OK] to delay.
The auto-on pre-alert time will commence again 1 hour
later at 6:55pm. If no further delays are requested system
will automatically turn All On at 7:00pm.

Remote Arming - Quick Arm

If you forget to arm your system it may be possible for
you to remotely arm it using a touch tone telephone if the
remote arm option has been enabled by your installer.
To arm the system call the number which the panel is
connected to and when the panel answers you will here 3
beeps in accending frequency if the panel is in the disarmed
condition. Press [0] + [#] to arm. You will hear 3 beeps in
decending order when the panel arms.
All areas on the system will be armed regardless of there
condition when using the DTMF quick arm function.

Duress or Silent Alarms

A Duress or Silent Panic alarm can be easily triggered via
the keypad if you are being forced to operate the system
against your will.
To trigger a duress, enter your normal user PIN followed by
the last 2 digits of your user PIN followed by the ON or OFF
key. See the following examples.
1) If your PIN is 2580, to send a duress report when the area
is off, Enter, [2] + [5] + [8] + [0] + [8] + [0] + [OK] or [ON].
2) If your PIN is 2580, to send a duress report when the area
is on, Enter, [2] + [5] + [8] + [0] + [8] + [0] + [OFF].

DTMF Control Functions

Your system's telephone line interface provides for
comprehensive DTMF control of individual areas and
outputs with full user PIN and TIMER GROUP access
verification.
Your installer will advise you which DTMF features have
been enabled on your system.
How to Use DTMF Control
1. Call the phone number which the panel is connected to
and when the panel answers you will here a short welcome
jingle. You now have approximately 5 seconds to enter a
valid PIN and log onto the panel.
2. Enter PIN followed by the # key. If the PIN is valid the
system will respond with two short beeps. If the PIN is
invalid then a single long beep will be heard.
If a valid PIN is not entered in time, the panel will attempt to
establish a modem connection which sounds very similar
Solution16