Oracle X5-4 Service Manual page 92

Hide thumbs Also See for X5-4:
Table of Contents

Advertisement

Clear Hardware Fault Messages
faulty -f [-a]
faulty -r [-a]
acquit <FRU>
acquit <UUID>
acquit <FRU> <UUID>
replaced <FRU>
repaired <FRU>
repair <FRU>
rotate errlog
rotate fltlog
4.
Use fmadm faulty and the following options to display active faulty components:
-a – Show active faulty components
-f – Show active faulty FRUs.
-r – Show active fault FRUs and their fault management states.
-s – Show a one-line fault summary for each fault event.
-u uuid – Show fault diagnosis events that match a specific universal unique identifier
(uuid).
For command specifics, see the Oracle ILOM User's Guide for System Monitoring and
Diagnostics for your version of Oracle ILOM at:
5.
Use fmadm to clear the fault.
When you clear a fault, you can specify either acquit, repair, replaced, or repaired for the
component in question.
6.
Close the Oracle ILOM session.
92
Oracle Server X5-4 Service Manual • December 2015
: display faulty FRUs
: display faulty ASRUs
: acquit faults on a FRU
: acquit faults associated with UUID
: acquit faults specified by
(FRU, UUID) combination
: replaced faults on a FRU
: repaired faults on a FRU
: repair faults on a FRU
: rotate error log
: rotate fault log
http://www.oracle.com/goto/ILOM/docs

Advertisement