Install a Power Supply
7.
Verify that the AC Present indicator is lit.
For more information, see
8.
If you performed a cold-service procedure, power on the server.
9.
Verify that the following indicators are not lit:
Service Action Required indicator on the power supply
■
Front and back Service Action Required indicators
■
Rear PS Failure indicator on the bezel of the server
■
See
for locations of system indicators.
Power Supply Reference
The server has two power supplies. This ensures reduncancy by allowing the server to operate
when one of the power supplies fails. However, when the server is operating on one power
supply, redundancy no longer exists, and the risk for an unexpected shut down and a loss of data
is high. When a power supply or any component that is part of a redundant configuration fails,
replace it immediately.
Power Supply Indicators
Each power supply contains an indicator panel. The following indicators are lit when a power
supply fault is detected:
Front and back Service Action Required indicators
■
Rear PS Fault indicator on the front bezel of the server
■
Service Action Required indicator on the faulty power supply
■
See
"Server Front Panel Features" on page 17
locations of system indicators.
140
Oracle Server X5-4 Service Manual • December 2015
"Power Supply Reference" on page
"Server Front Panel Features" on page 17
140.
and
"Server Back Panel Features" on page 18
and
"Server Back Panel Features" on page 18
for