Replace the Motherboard (FRU)
See
"Replace the NVMe Switch Card Cables (FRU)" on page 215
Gb/s Internal HBA SAS Cables (FRU)" on page
37.
To ensure proper cooling through the disk backplane area, slide excess cable
length of the SAS, NVMe (if present) and ESM cables towards the PCIe card area.
Reconnect the fan board power and data cables to the motherboard.
38.
Note -
panel lights and the fans will not spin up at power on.
39.
Install all memory risers.
See"Install a Memory Riser Card" on page
40.
For a two-CPU system, install the air baffle.
The air baffle is simply lowered into place on the motherboard utilizing available memory riser
slot guides. It does not attach to anything.
41.
Install all PCIe cards.
See
"Install a PCIe Card" on page
Reconnect internal SAS, NVMe (if present) and ESM cables, and external cables as applicable.
Install the SP card.
42.
See
"Install the SP Card (FRU)" on page
Prepare the server for operation.
43.
See
"Prepare the Server for Operation" on page
Note -
need to be reprogrammed by authorized service personnel with the correct product serial
number.
258
Oracle Server X5-4 Service Manual • December 2015
If the fan board connectors are not reattached to the motherboard, there will be no front
The product serial number used for service entitlement and warranty coverage might
204.
152.
164.
245.
259.
and
"Replace the SAS 12