Oracle X5-4 Service Manual page 87

Hide thumbs Also See for X5-4:
Table of Contents

Advertisement

See
"Prepare the Server for Cold Service" on page
Press and hold the system Fault Remind button.
2.
The Fault Remind button is located on the divider between the cooling zone 1 and cooling zone
2.
3.
Verify that the system Fault Remind circuit is usable.
When the Fault Remind button is pressed, the Fault Remind power indicator illuminates (green)
to indicate that the remind circuitry is usable.
4.
Look for the lit Fault indicators:
If the circuit is usable, identify the failed component by the lit Fault indicators. Use the
information in the following table to help you find the component.
Faulted Component
CPU
Memory riser card
DIMM
Memory Riser Indicator
CPU Indicator
On
On
The indicators for both
memory riser cards
associated with the failed
CPU turn on.
On
Off
On
Off
To locate the failed DIMM,
remove the MR card
Locate a Failed Memory Riser Card, DIMM, or CPU
94.
DIMM Indicator
Off
Off
On
Servicing the Server
87