Servicing PCIe Cards

135 Sun May 21 00:53:57 2000 DIMM Service Required Memory P0/MR0/D9 (CPU
Memory Riser 0 DIMM 9)
A failure has occurred during Memory Reference Code (MRC) DIMM module
training. (Probability:100, UUID:2a182715-983f-c4fb-e94f-b5a5b50d3650, Part
Number:001-0003-01,HMT42GR7AFR4A-PB, Serial Number:00AD011321345849FF,
Reference Document:http://support.oracle.com/msg/SPX86A-8004-67)
126 Sun May 21 00:53:56 2000 DIMM Service Required Memory P0/MR0/D6 (CPU
Memory Riser 0 DIMM 6)
A failure has occurred during Memory Reference Code (MRC) DIMM module
training. (Probability:33, UUID:9014a82c-7bf9-ee96-b61b-9c7ccedc9aed, Part
Number:001-0003-01,HMT42GR7AFR4A-PB, Serial Number:00AD01132129B11E9E,
Reference Document:http://support.oracle.com/msg/SPX86A-8004-67)
In this scenario, the DIMM in D6 failed at 00:53:56, and that failure is subsequently followed
by a reported failure of the DIMM in D9, which failed at 00:53:57. Both DIMMs are on the
same memory riser card (P0/MR0). Each DIMM is on a separate channel, but both are linked
to the same memory buffer ASIC. Additionally, all of the DIMMs in both channels might have
been disabled by the system. This scenario could be an instance of a multi-DIMM failure state.
How to Troubleshoot a Multi-DIMM Failure State
To troubleshoot this issue, replace only the DIMM that logged the initial failure and return the
server to operation to see if the multi-DIMM failure state persists. If a multi-DIMM failure state
had occurred, replacing only the DIMM that failed initially would rectify the fault state of the
initial DIMMs and the subsequent DIMMs. If the failures persists, the issue could be with the
DIMMs or with the memory riser card.

Servicing PCIe Cards

This section provides procedures for removing and installing PCIe cards and PCIe card filler
panels.
"Remove a PCIe Card" on page 161
"Install a PCIe Card" on page 164
"PCIe Slot Reference" on page 167
Note -
Oracle NVMe Switch PCIe card are only serviceable by Oracle Service personnel, see
"Servicing the Factory Installed SAS 12 Gb/s Internal HBA and ESM" on page 200
"Servicing the Factory Installed PCIe NVMe Switch Card" on page
160
Oracle Server X5-4 Service Manual • December 2015
The factory installed Oracle Storage 12 Gb/s SAS RAID PCIe HBA (Internal) and
or
212.