Remove a Heatsink and CPU (FRU)
5.
Open the spring-loaded CPU load plate release levers by pushing them down
and moving them slightly toward the CPU socket and away from their retaining
clips
The levers are numbered by their required order of operation. The left-side lever (when viewed
from the front of the server) must be opened first.
Rotate the levers to the fully-open position.
6.
When the second lever is in its fully-open position, the load plate is unlocked.
7.
To open the load plate, lift the unhinged end to its fully-open position.
Caution -
the CPU, use the correct CPU replacement tool.
8.
To remove the CPU, use the CPU replacement tool:
The tool is used to remove and install the CPU in the socket. The top side of the replacement
tool has a button in the center and a tab on one side. Pressing down on the button opens the tool.
Pressing the tab closes the tool (and releases the button).
190
Oracle Server X5-4 Service Manual • December 2015
Component damage. The pins of the CPU socket can be easily damaged. To remove