Remove a Fan Module
The Service Action Required indicators are located on the fan module. A lit amber color
Service Action Required indicator identifies a faulty component. For more information, see
"Fan Module Reference" on page
4.
Lift the green handle on the fan module and use it to pull the module straight up
and out of the server.
Caution -
removal can cause damage to the internal connector on the fan module board. When removing a
fan module, do not rock it back and forth.
"Install a Fan Module" on page 133
Next Steps
132
Oracle Server X5-4 Service Manual • December 2015
135.
Component damage. Excessive movement or rocking of the fan module during