User Guidelines
This command configures the maximum number of ingress ports that are
capable of transmitting into a single egress port (i.e., the maximum number
of talker registrations on a switch). If the fan in is reduced below the number
of active registrations, the switch attempts to remove the lowest priority
registrations until the fan in limit is reached.
Command History
Introduced in version 6.2.0.1 firmware.
Example
This example configures the fan in to 14 interfaces.
console(config)#msrp max-fan-in-ports 14
console(config)#show msrp summary
MSRP Global Admin Mode......................... Enabled
MSRP Talker Pruning............................ Enabled
MSRP Maximum Fan-in Ports...................... 14
MSRP Boundary Propagation...................... Enabled
QAV class A priority........................... 4
QAV class A remap priority..................... 1
QAV class B priority........................... 3
QAV class B remap priority..................... 1

msrp srclass-pvid

Use this command to configure the MSRP VLAN ID for the SR traffic class
on the interface.
Syntax
msrp srclass-pvid vlan-id
no msrp srclass-pvid
vlan-id—The VLAN ID of the MSRP SR traffic. The range is 1–4093.
Default Configuration
By default, VLAN 2 is used to carry SR traffic.