Technical data
10.2 Technical data, Power Modules
Property
Short-circuit current rating
(SCCR)
Electromagnetic compati-
bility according to IEC/EN
61800-3
Braking methods
Degree of protection ac-
cording to EN 60529
Ambient temperature
Ambient conditions accord-
ing to EN 60721-3-3
Temperature during stor-
age according to EN
60721-3-3
Cooling air
Relative humidity
Pollution according to EN
61800-5-1
Shocks and vibration ac-
cording to EN 60721-3-1
Installation altitude
Approvals
434
Version
FSA ... FSC ≤ 100 kA rms
FSD ... FSF ≤ 65 kA rms
Branch protection and short-circuit strength according to UL and IEC
(https://support.industry.siemens.com/cs/ww/en/view/109479152)
Devices with integrated filter are suitable for Category C2 environments.
DC braking, compound braking, dynamic braking with integrated braking chopper
Chassis de-
IP20
vices
IP20,
PT devices
IP54
FSA ... FSC:
LO base load power without derating:
HO base load power without derating:
LO/HO base load power with derating:
FSD ... FSF:
LO base load power without derating:
HO base load power without derating:
LO/HO base load power with derating:
Restrictions for special ambient conditions (Page 469)
For the maximum permissible ambient temperature, also observe the permissible ambient
temperatures for the Control Unit and possibly operator panel (IOP or BOP-2) .
FSA ... FSC
Protected against damaging chemical substance, according to environmental
Class 3C2
FSD ... FSF
Protected against damaging chemical substance, according to environmental
Class 3C3
-40 °C ... +70 °C
clean and dry air
< 95%
suitable for environments with degree of pollution 2, condensation not permissible
Long-term storage in the transport packaging according to Class 1M2
Transport in the transport packaging according to Class 2M3
Vibration in operation according to Class 3M2
without derating
with derating
Restrictions for special ambient conditions (Page 469)
FSA ... FSC
cULus, CE, C-tick, KCC
FSD ... FSF
cULus, CE, C-tick, SEMI F47, KCC, WEEE, RoHS, EAC
Must be installed in a control cabinet
Must be installed in a control cabinet
at the control cabinet panel
-10 °C ... +40 °C
-10 °C ... +50 °C
-10 °C ... + 60° C
-20 °C ... +40 °C
-20 °C ... +50 °C
-20 °C ... + 60° C
up to 1000 m above sea level
up to 4000 m above sea level
Operating Instructions, 01/2016, FW V4.7 SP6, A5E31759476B AE