Dimensioned Drawings, Drilling Dimensions For The Pm240 Power Module, Fsa - Siemens sinamics G120 Operating Instructions Manual

Low voltage inverters chassis devices with cu250s-2 control units and encoder evaluation
Hide thumbs Also See for sinamics G120:
Table of Contents

Advertisement

4.4.4

Dimensioned drawings, drilling dimensions for the PM240 Power Module, FSA

... FSF
The following dimensioned drawings and drilling patterns are not to scale.
Table 4- 5
Frame size
FSA
FSB without/with filter
FSC without/with filter
FSD without filter
FSD with filter
FSE without filter
FSE with filter
FSF without filter
FSF with filter
The Power Modules can be mounted and operated side-by-side. For tolerance reasons, we rec-
1)
ommend a lateral clearance of approx. 1 mm.
Converter with CU250S-2 Control Unit
Operating Instructions, 01/2016, FW V4.7 SP6, A5E31759476B AE
Mounting dimensions
Width
153
189
275
275
275
275
350
350
(mm) Height (mm)
1)
73
173
270
334
419
512
499
635
634
934
4.4 Installing Power Modules
Depth (mm)
with shield connec-
tion kit
271
360
432
542
635
622
758
792
1092
Installing
145
165
185
204
204
204
204
316
316
65