Advanced commissioning
6.2 Inverter control
6.2.10.6

Position actual value of the encoder

G1_XIST1 and G2_XIST1
In the factory setting, the inverter transfers the encoder position actual value with a fine
resolution of 11 bits to the higher-level control system.
Image 6-15
The transferred encoder signal has the following properties:
● After the inverter power supply has been switched on, the encoder signal = 0.
● The higher-level control must be able to handle a counter overflow of the encoder signal.
G1_XIST2 and G2_XIST2
In G1_XIST2 or G2_XIST2, the inverter transfers different values to the higher-level control
system:
Encoder x parked
Encoder fault x
Referencing encoder x
Image 6-16
184
G1_XIST1 and G2_XIST1
Gx_ZSW.14 = 1
Gx_ZSW.15 = 1
Gx_ZSW.4 = 1 or Gx_ZSW.5 = 1 or Gx_ZSW.6 = 1 or Gx_ZSW.7 = 1
G1_XIST2 and G2_XIST2
Operating Instructions, 01/2016, FW V4.7 SP6, A5E31759476B AE
Converter with CU250S-2 Control Unit