Item No.
U034
5. Change the setting value using the cursor +/- or numeric keys.
For output example 1, increase the value. For output example 2, decrease the value.
6. Press the start key. The value is set.
Remark
When changing the setting value of [Large] each item is modified, equal to amount of the value
which is changed adds also the value of [Small] each item and is pulled.
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following
adjustments in maintenance mode.
U034
Adjustment: LSU Out Left
1. Press the system menu key.
2. Press the start key to output a test pattern.
3. Press the system menu key.
4. Select the item to be adjusted.
Display
MPT
Cassette1
Cassette2
Cassette3
Cassette4
Cassette5
Duplex
Service Manual
Leading edge
registration
(20 ± 1.0 mm)
Correct image
U066
(P.1-3-49)
Description
Paper feed from MP tray
Paper feed from cassette 1
Paper feed from cassette 2
Paper feed from optional cassette 3
Paper feed from optional cassette 4
Paper feed from optional cassette 5
Duplex mode (second)
Description
Output
example 1
Figure 1-3-4
U071
(P.1-3-54)
Setting
range
-3.0 to 3.0
-3.0 to 3.0
-3.0 to 3.0
-3.0 to 3.0
-3.0 to 3.0
-3.0 to 3.0
-3.0 to 3.0
1-3-34
2LL/2LJ/2LH
Output
example 2
Initial
Change in
setting
value per step
0
0.1 mm
0
0.1 mm
0
0.1 mm
0
0.1 mm
0
0.1 mm
0
0.1 mm
0
0.1 mm
Y113350-5